Use LDSOLAR Controller Build Off-grid Solar System
Rated charge current: 50A 60A
Terminals: Customized large Terminals
Use LDSOLAR Controller Build Off-grid Solar System
Tracer Dream 150V TU Series
50A /60A 12V-24V-48V
Max.150V Solar Input
Tracer Dream 150v TU Series adopts MPPT technology.Max.150v solar input,12v/24v/48v auto work.it's also ran by 32 bits CPu,sostability and speed can be guaranteed. Based on the synchronous rectifier technology,the transfer eficiency of circuit can beincreased up to 98.59% and the Pmax tracking accuracy up to 99. 5%.so our MPPT can trace the accurate Pmax in the shortest time(10~20s) ,even when the sunlight changes rapidly. lt can perfectly handle extreme weather or weak sunlight.t adopted by commonnegative design and it can start from solar,Widely used in solar station and big solar home system
Product Details
The controller adopts asymmetrical design, and the LCD
screen is located at the golden section, with a harmonious
proportion and beautiful appearance.
Highlights
The Tracer Dream 150V TU Series Solar Charge Controller combines advanced digital technology with robust construction to deliver superior performance. Key features include:
Parameter
Detailed explanation of specific parameters
Item | TD4515TU | TD4615TU |
System nominal voltage | 12/24/48VDC Auto ① | |
Rated charge current | 50A | 60A |
Battery voltage range | 8~68V | |
Max. PV open circuit voltage | ② 150V ③ 138V | |
MPP voltage range | (Battery voltage +2V)~ 108V | |
Max. PV input power | 600W/12V 1200W/24V 2400W/48V | 800W/12V 1600W/24V 3200W/48V |
Self-consumption | ≤70mA(12V)/40mA(24V)/24mA(48V) | |
LVD | 11.0V ADJ 9V….12V;×2/24V;×4/48V | |
LVR | 12.6V ADJ 11V….13.5V;×2/24V;×4/48V | |
Float voltage | 13.8V ADJ 13V….15V;×2/24V;;×4/48V | |
Boost voltage |
14.4V ; ×2/24;×4/48V Battery Voltage less than 12.6V Start Boost changing for 2hours(Li-battery not) |
|
Discharge circuit voltage drop | ≤0.12V | |
MPPT tracking efficiency | ≥99.5% | |
Max. Conversion efficiency | 98% | |
Grounding | Common negative | |
Battery Type | Sealed(Default)/Gel/Flooded/LiFePO4/ Li(NiCoMn)O2/ User | |
Temperature compensate Coefficient④ | -4mv/℃/2V | |
Dry contact | Rated value: 1A/30VDC; Max. value: 0.5A/60VDC | |
Communication method | RS485(5VDC/200mA) | |
LCD backlight time | Default: 15S | |
Working environment temperature◆ | -20℃~+50℃(100% input and output) | |
Storage temperature range | -20℃~+70℃ | |
Relative humidity | ≤95%, N.C. | |
Enclosure | IP32 |
①When a lithium battery is used, the system voltage can’t be identified automatically.
②At minimum operating environment temperature
③At 25℃ environment temperature
④When a lithium battery is used, the temperature compensate coefficient will be 0.
◆The controller can work under full load in the working environment temperature, When the internal temperature is more than 80℃, the reducing power charging mode is turned on.
Installation Diagram
Please be sure to follow the wiring instructions as incorrect wiring can cause damage to the controller.