Uti Ldsolar controller aedificare off-eget solaris systematis
Currens electricus aestimatus:10A 20A 30A 40A 50A 60A
Terminales : Terminales magni ad personam facti (Rubri/Nigri)
Utere moderatore LDSOLAR ad systema solare extra retia construendum.
Series Somniorum Indagatorum
10A / 20A / 30A / 40A /50A / 60A
12V-24V / Maximus 60V/100V Input Solaris
Series Tracer DreamS technologiam MPPT adhibet. Praeterea, CPU 32-bit operatur, ita stabilitas et celeritas praestari possunt. Innixa technologiae rectificatoris synchroni, efficientia translationis circuitus usque ad 98% augeri potest, et accuratio Pmax ad 99.5% persequendi. Itaque MPPT nostrum Pmax accurate investigare potest brevissimo tempore (10~20s), etiam cum lux solis celeriter mutatur. Tempestates extremas vel lucem solis debilem perfecte tolerare potest.
Singula Producti
Involucrum album integratum lineis levibus
Idoneum ad necessitates visuales domus, mercatus, industriae, aliorumque scenariorum
Notabilia
Regulator Solaris Impletionis Tracer Dream Series S technologiam digitalem provectam cum constructione robusta coniungit ut praestantiorem efficaciam praestet. Inter proprietates praecipuas sunt:
Parametrum
Explicatio accurata parametrorum specificorum
| Res | TD2106S | TD2206S | TD2110S | TD2210S | TD2310S | TD2410S | TD2510S | TD2610S |
| Tensio nominalis systematis | 12/24VDC Automaticum ① | |||||||
| Currens oneris aestimatus | 10A | 20A | 10A | 20A | 30A | 40A | 50A | 60A |
| Currens exonerationis aestimatus | 10A | 20A | 10A | 20A | 30A | 30A | 30A | 30A |
| Ambitus tensionis pilae | 8~32V | |||||||
| Maxima tensio circuiti aperti PV | ② 60V ③ 55V | ② 100V ③ 95V | ||||||
| Ambitus tensionis MPP | (Tensio pilae +2V) ~ 50V | (Tensio pilae +2V) ~ 75V | ||||||
| Typus Batteriae | Obsignatum (Default) / Gel / Inundatum / LiFePO4 / Li(NiCoMn)O2 / Usor | |||||||
| Potentia oneris aestimata | 130W/12V 260W/24V | 260W/12V 520W/24V | 130W/12V 260W/24V | 260W/12V 520W/24V | 390W/12V 780W/24V | 520W/12V 1040W/24V | 650W/12V 1300W/24V | 750W/12V 1500W/24V |
| LVD | 11.0V ADJ 9V….12V;×2/24V; | |||||||
| LVR | 12.6V ADJ 11V….13.5V;×2/24V; | |||||||
| Tensio fluctuationis | 13.8V ADJ 13V….15V;×2/24V; | |||||||
| Tensio amplificata | 14.4V ADJ14V….17V; 2/24; Tensio batteriae minor quam amplificatio. Tensio denuo incipiendi amplificatio mutatur per duas horas. | |||||||
| Autoconsumptio | ≤28mA (12V) ≤19mA (24V) | |||||||
| Tensio circuitus exonerationis diminuta | ≤0.12V | |||||||
| Coefficiens compensationis temperaturae ④ | -4mV/℃/2V | |||||||
| Temperatura ambientis laboris◆ | -20℃~+40℃ (100% ingressus et egressus) | |||||||
| Ambitus temperaturae repositionis | -20℃~+70℃ | |||||||
| Humiditas relativa | ≤95%, N.C. | |||||||
| Claustrum | IP30 | |||||||
①Cum accumulatore lithio adhibetur, tensio systematis sponte cognosci non potest.
②Ad minimam temperaturam ambitus operandi
③Ad temperaturam ambientis 25℃
④Cum accumulatore lithio utitur, coefficiens compensationis temperaturae erit 0.
◆Moderator sub pleno onere in temperatura ambientis laboris operari potest. Cum temperatura interna plus quam 80℃ est, modus onerationis potentiae reductricis activatur.
Schema Installationis
Quaeso instructiones filorum coniunctionis sequere memento, nam filatio incorrecta damnum moderatori inferre potest.